MEチェスト1. 12. The only cable that can handle 32 channels is ME Dense Cable that can be branched off of by ME Glass Cable. • 4 yr. Creating this device is extremely expensive due to it requiring a Quantum Link Chamber in the center, and eight Quantum Field Rings around it. When I started my Applied Energistics 2 setup I used 2x2x4 pillars consisting of 8 ME Interfaces and 8 Molecular Assemblers. ME Controller may refer to: ME Controller (Applied Energistics) ME Controller (Applied Energistics 2)Applied Energistics 2’s Channels. Storage size Small Big Minimal Machine automation Yes No Only highly required (better fed by automation system) Long. I opted to use Minetweaker to remove that barrier to entry. Use a quartz cable to connect the smart cable to the ME controller hub, the huge one and remove the intermediate controller. So you can have as many inserters (conduits) and belts and whatever items that you need to automate your factory. But in Minecraft you need to. 6. 7. (3) 5 inscribers. Theinventor10. The P2P network will transfer power, but won't use power it's transfering. Or so I heard. As I continue to dabble I may add in checking on the status of the requested jobs and bound the looping to when all requested jobs per loop-pass have been completed. ago. My Very First Quartz. The CPU must be a cuboid, completely composed of the parts listed above; air or other blocks are not valid. I have a 5x5 big reactor supplying sufficient power. It transmits ME Network data remotely to the synchronised Wireless Terminal allowing remote access to the Network storage. 7. AE2 has a 'spatial storage' component. 4kRF) and i can't seem to get any more energy into the system with energy acceptors. Smart, covered, or normal ME cable = 8 channels carrying capacity. If you still want to be able to craft the controller, then you need to add a custom recipe for it. The main feature of Applied Energistics 2 is the ME Network ( pronounced Emm-Eee and stands for Matter Energy ), which is a set of connected blocks, and cables grouped into a system, where storage, power and functions cooperate between multiple components. The ME Molecular Assembler Chamber must be a minimum of 3x3x3 block cube. The only catch is that you have to run a separate p2p tunnel to access the auto crafting capabilities. Place the storage bus on the ssn controller and use the cable to connect to your ae2. D:powerUsageMultiplier= used to adjust power requirements on all of ME tech, muliplied by base costs durring calculations. Machines operate at max speed (resonant + the 3 speed upgrades). ) and Energy Units (EU). them outside the network. I think this might give more channels per controller (128 per controller vs 124) but I might be wrong. If you want to see if you can access your ssn from your ae2 you'll need everything above plus some ME cables and a storage bus. (4) some EnderIO item conduits. Now its working to the maximum potential it has. Read below for info and updates on the subject!Fantasy This page is about the ME Controller added by Applied Energistics 2. Unknown. 0 the mod does not depend on the minerkaft version! The mod allows you to: -Remove channel restrictions; -Connect controllers via cable; -Expand or shrink maximum multiblock size from controllers. The Controller will need power to work. MeefMagnet goes through how to increase the size of your ME Controller and how to reorganize it for maximum usable channels. A Sky Factory 4 Tutorial on how to setup a basic Applied Energistics ME System. AE2 Auto-crafting becomes a balancing act between speed and efficiency, while also having to keep channels in mind. 12. Any data-storing or data-using device needs a channel. • 1 yr. Top 1% Rank by size . ME Cable is added by Applied Energistics. Dense, P2P and Quantum Ring all support 32 channels. Here's something that uses. The machine requires either a Wooden Crank (placed on top of the block) or power in the form of Redstone Flux (RF), Energy Units (EU), and Teslas (Energy can only be inserted from. Setting the Storage Bus to a high priority should be all you need to ensure items always go there first. Applied Energistics 2 (AE2) is a mod for Minecraft that adds advanced storage and automation systems to the game. The primary defining difference between AE1 and AE2 is channels, but not the only. The me_interface provides the Common Network API and the following: getInterfaceConfiguration ( [slot:number]):table. 4. (16x16 area) Describe the feature: +1 range from the controller. The bus priority should be extremely high, set it to 10000 to be positive. They're both visually appealing in their own ways to me. The ME Controller was only really necessary for when there are channels. I already have dense cables running through my entire system, so that's not going to be a problem. I suggest using a Bulk Storage solution, and then for general storage. Or just do the level emitter thing, or external automated crafters and pre. Crafting CPU. The main reason I may choose to put down more Controllers, say a 1x5 block, is to make it a bit easier to attach cables to it without making a mess. I agree, you can pretty much do everything a well equipped base needs with 1 controller and a few dense cables (or p2p, if you want). To set up a network there are only a few things needed: exactly one ME Controller (it won't work if you have more) a power source connected to your Controller. The ME P2P Tunnel is a block added by the Applied Energistics mod. After the move I. one ME Access Terminal or ME Crafting Terminal if you have chosen an ME Drive as your first Storage. A ME Controller can have 2 adjacent blocks in at most 1 axis; if a block violates this rule, it will disable and turn white. It's the best balance between capacity and storage space. it's probably because of nested recipes, calculations will take forever to calculate tier 1 essence -> tier 2 -> tier 3 -> tier 4 -> tier 5 -> tier 6 essences needed to craft each tier of seeds. I've been playing on my E2E on and off for about a year now, and I recently decided to upgrade my base and AE2 ME system setup. Whenever you have more than 8 devices in a network, an ME Contr. Notifications Fork 556; Star 1. The ME Controller allows you to start a ME network within minecraft. As far as I am aware those are the only restrictions. I'm pretty sure I've seen people do wall of drives, which would mean <n> drives x 10 <disks x 63 <item types> * <average NBT size across all drives> space is needed. Il s'agit d'une version nouvelle et améliorée du mod Applied Energistics original. I. Two ME Controller blocks make a 1 x 2 multiblock structure which has a total of ten faces, or 80 channels with regular ME Cable. 3 sides total of 24 channels instead of using 4 sides using 4-6 channels. 2 2.グラインドストーンを作る. Each device takes one channel. In games like Factorio, getting resources is automated right away. A creative build where I tried to max out an ME Controller, to get as many channels as possible available for usage. Each one of those can handle a several more channels. CurseForge is one of the biggest mod repositories in the world, serving communities like Minecraft, WoW, The Sims 4, and more. 11. In practice the amount of channels you actually need comes down to how much you intend to solve with AE2 and the modpack you are playing. e. ). That means it can transfer 16krf/t. It has to be touching the drawer bank. The crafting CPU as a multi-block only requires a single channel for the entire. Although the chest's storage capacity is limited to one Cell, it has it's purpose. You could have 32 Input P2P tunnels feed into one dense cable and then into one side of a Controller, and the output tunnels will be on the other side of the controller. Applied Energistics 2について. Also a 3x3 square would not work due to the way they work. . You can tell this by watching the AE controller energy go above its max amount before resetting back to its max amount and repeating. 4 4.MEネットワークを構築する. It is used to charge charged items and charge Certus Quartz Crystals into Charged Certus Quartz Crystals. seannyyx. With that many ME drives, you'll need a lot of power (at default conversion, 224 RF/t just for the drives if you used 1k storage cells in all of them, or 704 RF/t if you used 64k storage cells; the power draws caused by the crafting terminal, storage bus, and cables are trickier to calculate). I've tried a few different ways to power the unit. 2 Steve's First Network . The item type cap is 61 *per drive*, so once you get 3-4 drives you're pretty much set. the energy acceptor is now passing power to the main network, which is passing it to. The barrier to entry for AE2 is terrible. Configuration file (ae2ao. 4mj/t for a ME drive filled with 4k vs 4. u/prozacgod came up with the idea of using a specific shape that has a large surface area that fulfils the maximum size of an ME Controller. For other uses, see ME Controller. Functional Storage is an alternative take on the storage solution of Storage Drawers, with an updated look and additional functionalities like: Armory Cabinet: It stores 4096 non stackeable items (by default) and can only be accessed with external tools (currently) like Applied Energistics or Refined Storage external storage tools. Controller mutliblock has to fit within a 7x7x7 - again, not too bad. a controller with infinite channels. If it's not ok, halve it, try again. An instant connection between any two points on an ME Network. And so forth. ) Things like ME Controllers, Inscribers or Crystal Growth Accelerators, do not use channels. When Ae2 blocks touch each other imagine there is an infinitely small cable connecting touching sides and that they behave like electrical wire. So the system keeps flickering on and off, we have no current power issues, I thought it could have been not enough power in the system so I added 3 cells, it didn't fix it, I. However!At the moment, my ME System is located underneath my Incense Altar Pyramid (Max size), but I am considering moving after I find a new base location. One dense cable gives 32 channels, which is enough to autocraft 288 items (9 items per interface; molecular assemblers don't require a. I just logged on and now its doing nothing at all :S really strange, i can access the system/items but its not processing anything and there are still ores and dusts in the system, also there. I don't hear people screaming "Spread your drives! Spread your drives!" so quite possibly AE2 has some other storage solution to prevent this. Here is a little breakdown of how I wired it. A Spatial Containment Structure or SCS, is a Multiblock networked structure that dictates a region of space as the target of the Spatial IO Port. The 63 types is a non issue for me. A single block controller could take in 3 dense cables and output 3 dense cables, meaning you would have access to 3 * 32 * 32=3072 channels from a single block controller. 10) and remove a couple of potentially confusing commented-out lines: OpenComputers 1. 4 Subordination: Respect My AuthoriTAY . Blue is RF into (into the LEC), orange is. The p2p network by itself is a normal ME network (with the one difference that it connects p2p tunnels instead of storage/crafting devices etc. Cheers! The ME Controller is a block added by the Applied Energistics 2 mod. Maximum size of the ME Controller multiblock is now configurable. If you max that out, that's 64 machines running on your 1 cable. To use - place 2 Wireless Connectors and right click both with a Wireless Configuration Kit. B:Channels=true. One actively pulls items, one passively accepts items. Almost right. Ah ok, so just a bigger set up I guess. Up to 64 Boosters may be inserted for a total range of 528 block radius and an energy cost of 4. It is the new and overhauled version of the original Applied Energistics mod. Taking this to the max, you can add a Controller and use Dense Cables. All others (max. Large RS systems are hell on the server and will cause lag spikes that can affect everyone for multiple seconds at a time if you are on multiplayer. (Crystal Growth Accelerator) 鉄インゴット:4+MEガラスケーブル - フルーシュ:2+クォーツガラス:2+フルーシュブロック:1. I usually have 2 dense cable coming out from the controller, that's face for connecting p2ps. Quick note, sticking the Cell into a crafting grid when it has no Items stored as data will also work to extract the component. One thing you will need to know when making a multiblock is that each controller can touch no more than 3 other controllers to remain valid. 64k disks would store a lot more per disk, but the index is 4x the size. It is not possible to have 2 ME Controllers in one ME Network, though a multiblock structure can be created. Minecraft Version: 1. AE2 makes you think about what you build rather than plopping down cables and other devices. It is highly recommended following its specification and further considering an upper bound for the dependency version. 6 6.バニラのチェストとアイテムの受け渡し. . This mod focuses on presenting. What I don't like about AE2's CPU is you need 3 parts: the CPU, an ME interface, and a molecular. As a sidenote here : Dont do massive Storage drawer arrays if you have an AE2 system use AE2 Storage cells, drawers in huge amount will lagg you to death at one point. Do what you normally would to join 2 p2ps and see whether it works. like it doesnt exist. アイテムをデジタルデータ化して貯蔵、運用するといった趣のMOD。. 2 始めに. Last modified on 03/09/2014 10:04 PM CDT. An expandable and versatile advanced data storage system with a multitude of applications. There is a way to circumvent this. AE2 network is small, 20 64K drives, 20 ME interfaces and 20 molecular assemblers but no patterns (issue happens with just controller). (5) some EnderIO basic conduit filters. A 3-block controller has 14 faces x 32 channels = 448 total channels. However ME Dense Cable can support up to 32 channels, the only other devices capable of transmitting 32 are P2P. Join. 5 Some examples of sub-networks and their use . lorilith. e. While holding shift will extract a full stack. This can be useful to move a multi-block stucture or a processing machine set-up. But in order for me to not pull my hair out and want to just not play until I finally hit some kind of epiphany in regards to this, I thought I'd ask for help in making a compact storage system of. Better to just learn how to manage channels with p2p, multiple controllers, and using anchors to separate bundles of dense cable. I just use a normal reactor with a huge capacitor bank to store power. extenders= the maximum number of wireless boosters ( capped at 64 ). No. 4kRF) and i can't seem to get any more energy into the system with energy acceptors. Not sure if this has been done before but this is how I do my molecular assemblers. Lazy AE2の導入方法. Glass, Covered and Smart cables all support 8 channels. We use to place the controller in the Overworld and connect with p2p tunnels the machines inside CM. Each face supports 32 channels. 8 in normal cables. One side of an ME controller can provide a bus for 32 systems. 3 Controlling the Network . Basic fluix cables have a maximum of 8 channels that can connect in a single branch. Get to know AE2 in a new way! - Download the Minecraft Mod AE2 Additional Opportunity by Domaman202 on Modrinth. . A big part of the struggle on the configuration shown is the reupdate + Light recalculation as ME Controller emit lights when on. E. To set up a network there are only a few things needed: exactly one ME Controller (it won't work if you have more) a power source connected to your Controller. when cheated it on online server or local/single player it acts like a 'stone block' its possible to edit it with the chisel and it becomes another block (like the chisel mod works) Minecraft Version: 1. . This is obvious but its still the best tip for ae2 but cable anchors can prevent cables that would otherwise connect from connecting. Import bus pulls items from an inventory into the ME system. Is AE2 storage infinite, or is it limited? AE 1 had infinite storage, as you could connect as many ME Drives as you wanted to a controller. Add a Comment. 今回はME Controllerをクラフトするべく様々な工業Modの要素を進めていきます。. Even mekanism has a system for it, though in this case its worse than. More info below!You can support me and the channel! Read more here: my first base I set up a 5x5 big reactor which was my power source for rf machines and ae2. dman11235 is on the right track, but to expand a bit. . Additional channels can be added to network via placing additional controllers adjacent to current controller (with a few structure rules) Dense lines from each side must be completely independent of another, or else the network interferes. Each block will use 10 + distance 2 AE/t (configurable)I dont really understand Ae2 nearly as much as i see most people do here on this sub, but Im trying to setup a large crafting grid of a 3x3x3 block, alternating between ME Interface's and Molecular Assemblers. Examples of these are enderio, project red, etc. Nov 21, 2014. 180. The ME crafting terminal a great block to add to your ME network. The main feature of Applied Energistics 2 is the ME Network ( pronounced Emm-Eee and stands for Matter Energy ), which is a set of connected blocks, and cables grouped into a system, where storage, power and functions cooperate between multiple components. com wrote: the existing config works, but i want that it only works with a me controller and the controller i cant find. 91. Server address is sb. No crafting recipe for the AE2 version only chisel. While the ME Chest is a great way to get introduced to the concept of ME, to really take advantage you need to. With channels/controllers disabled you no longer have to worry about how many connections are on a line. mc-complex. P2P Tunnel or "Point to Point Tunnels" are a versatile configurable system to move items / redstone / power / and fluids from one location to another though an existing ME Network without storage. I've attached leadstone pipe directly to the unit, but it didn't make a connection. Flammable. 94. All Spatial Pylons must be either connected with cable or via a QNB, and on the same network. For logistic pipes, you have xnet for automation, and you could rush integrated dynamics. 1 Definitions and conceptual implications . 1 AE2 Channel Surfing for Newbies (A Reference Guide for the Rest Of Us!) 1. Top: Double-compressed item Lower-left: Compressed item Lower-right: Base item Extracting is performed with the left mouse button. The AE2 wiki says, the ME Storage Bus needs its own channel. However, you will need to reconnect a P2P bus (per dense cable). I have a question regarding AE2. When taken by itself, the ME Controller does nothing. I'll tell you what are the differences between them, How to build a Hilber. I was partly going for wanting it to look a bit diff anyhow. The first tier of AE2 tech, such as the , Certus Quartz Wrench, Certus Quartz Cutting Knife, and Certus Quartz tools, uses Certus Quartz as the primary crafting ingredient. 2. Screenshots. all sides of the controller are fully functional and plugged in to each other creating one massive controller with the ability to add more sections if i need more channels. malicious_bloke. AE2 current setup. total size 29x29x9. If. Side note: this is being done in the mining dimension since server restrictions keep me from doing all this in my main stoneblock base. . 432. I imagine one day I'll need those extra channels in which case I'll rip out this design and likely opt for the max size beast. If that doesn't work they aren't compatible and you should instead build some import busses to start. You can't have more than 1 controller on a network, but adjacent controllers form a multiblock, allowing more sides. While hovering over an item that has a guide page, hold the W key to open the corresponding guide page. At its most. The storage cell can be formatted before use to only accept certain items in the Cell Workbench. 25kRF/t generated and consumed, but when the autocrafting is going it drains the pitiful reserves of the controllers (16kRF/controller, max power is 304. Not too shabby. Since the release of AE2, I've only kept basic networks (crafting terminal, controller, me drive, interfaces connected to machines). Just out of pure curiosity, has anyone built or does anyone know that max number of channels that can be created from joined ME controllers? I know that the max size is 7x7x7, and that you can only have 3 blocks in a row without an air gap. Once our network grew to a certain size, with multiple quantum bridges and numerous storage mediums added, we starting having troubles with things disappearing from our ME network. When you exceed 8 devices, the network channel using the device turns off, you can remove the device or add a ME Controller. 5 Some examples of sub-networks and their use . Read below for info and updates on the s. No cards, no items, only. Simply put you're "tunneling" up to 32 channels of information from one point to another. Remember that AE devices link to each other and connect to the network. 5 5.入出力端末を作る. The ME Controller allows 32 channels to be used per side. The rules for a valid SCS are, A minium size of 3x3x3 ( this will capture a single block. The ME Network is a multi-block structure added by the Applied Energistics 2 mod. I'm still not able to find out how I can connect a secondary terminal 50 blocks away though. The power source is a vibration chamber, i assumed it didnt need a power acceptor since it have ae directly. Normally in the inside of a corner you can't get 32 channels out of each face as if you place a cable there it'll connect to both faces and only let 32 channels through itself, wasting anywhere from 32 channels in a regular corner, and 128 in. The ME 1k Storage cell is the smallest and easiest to craft to get started, and can easily. 0:00 / 9:22. Applied Energistics 2. It can be small or big, but only one per network. Thi. 2Applied Energistics 2. The mod's Energy Acceptor and Controllers accepts both Forge Energy (FE, RF, µI, CF, IF, etc. I have an Empowerer from Actually Additions 2, but it seems to be fighting for bandwidth with my Molecular Assemblers. 7. ). you are also advised to use storage drawers with ae2. P2P Tunnel. 2. In the case of AE2's assemblers, that's probably going to mean a controller, a single assembler block, a memory block, and a hard drive; but again, I'm guessing. There can be one controller on a network at most. ME Controller • ME Covered Cable. It accepts energy in from most sources, such as EU and MJ and provides it to the machines connected to it. Each block may have 2 adjacent. RS's versions have Stack and Speed Upgrades which both. miner49er is correct 1 dense cable can give out 1024 channels. But now whenever I connect the quantum network bridge to my controller it immediately drains it of power and shuts down the entire network. networkfeatures {. P2P ME tunnels and controllers can transmit up to 256 channels: RU: (рекомендуется использовать этот мод вместе с. To get the full 32, you need to use DENSE me cable, which is kind of a pain to craft, but it will allow the full 32 channels to accessed. at least one Storage Block (ME Drive or ME Chest) The following are rather optional. ME Controller · ME Power Relay. #1. ---> I only have 3 blocks in a row. So within rule 2, there are 6 corner blocks (max 3 connections), 60. r/feedthebeast. (MAs), and to surround your Interfaces with 6 MAs each (like most AE2 blocks, MAs do transfer channels). Considering the vanilla item system, AE2 is even great at handling non-stacking items as long as their data is consistent (in particular, freshly crafted items). After implementing AE, I have a 5 block storage network, the contents of which can be. ME Controller • ME Covered Cable. 12. It's basically like taking a storage cell and limiting it to only hold one or 2 or how ever many, really different items. Adding a second would allow 128 more channels, I would say that's a pretty big step. 3 Controlling the Network . Today I gonna show you how to use the cables from Applied Energistics 2. It is used to connect the components of a ME Network. A Network requires power, which can be provided by various blocks, and may require ME. It allows items to be inserted into or extracted from the ME System it is connected to. You do not have to build the multiblock as a cube though. Hello, want to know why the MB limit is 17x17x17? This a max amount of 314. 2852;. I don't know if I can change the flair to. This allows the mod (Applied Energistics 2) to accept multiple forms of power, but not be a totally broken power converter. 2; Forge; Nov 7, 2023;. A 4k disk is 4x the size and cost of a 1k disk and the index is 4x bigger. )液体の管理に使用する装置も専用のものが追加されています。MEコントローラやMEドライブまたはMEチェストはAE2のものと同じものを使いますが、液体の管理をするときはドライブかチェストにME液体ストレージセル(ME Luqid Strage Cell)を入れて使用します。液体. So for example, if you have an ME Cable facing all six sides, you can have a maximum (assuming no one cross-connects) of 48 channels from a single ME Controller. But most AE2 machines still need power. Each face of the Controller has 32 Channels, and items using channels trace the shortest path they can back to the Controller. I wouldn't suggest a turbine until you can use the power of a max size one which is 80 blades, uses 2000 mb/t of steam, and produces around 27k RF/t depending on the power multiplier in the configs. As your base network grows larger and larger, you will need to have at least one ME controller to hook up more devices to the network (a single controller gives 196 channels, or up. 2) Wire the 5 p2p ends from the other side, the top 2, and the top 1 on the back side. AE2 itself adds Certus Quartz Crystal, and makes use of vanilla's Nether Quartz as well. you can also use the Cell Workbench to blacklist or whitelist cells to accept or block certain items then use the IO Port to transfer items from the cell to the system. Since all the tunnels connect directly to the controller and are equal to a length 1 hop, the channels will never route sideways through the machines. If there's "Extra Cells 2" in your pack, the biggest storage cells are 16M (instead of 64k). you are also advised to use storage drawers with ae2. It is still awesome. My attempt at a. According to my own calculations, the maximum amount of items you can store is somewhere are 20,000,000. 超圧縮し省スペース化を実現する大容量チェスト、洗練されたアイテム輸送等、 貯蔵&輸送 に特化した装置を追加する。. Each side of ME controller provide 32 channels. ago. One click will extract a single item. An ME interface allows you to pump things into it. But you have to supply it with one of the following forms. The ME Controller's texture will change to display the stored energy level for network use. I wanted to build a 30x10xn (n = 3 or more layers) but after I place the 18th bl. The developers of the pack have turned off AE2's channel system, if you'd like to re-enable it, consider the following: Find modpack's files -> Open config folder -> Find "AppliedEnergistics2. Yes, those conversions are one-way (AE2 is not an open power converter). They are capable of transmitting 32 channels, which you can expand. Join. All reactions. Controllers are a free-form Multiblock with various build rules. An import bus takes a channel, a disk drive takes a channel, a terminal takes a channel, every machine takes up just one channel. If you hook that up to any storage and connect it to your your system all the items in said storage will now be visible to the system. (4th picture) So if you make each set of the controllers max size and have all the faces connect to the center network you can have ALOT of channels. If dyed, cables will not connect to ones of a different color, which makes it easier to have many networks close together. If it's ok, cancel and double it, try again. R. The ME Controller has a maximum length of 7 blocks total B. This device also requires a large amount of power to operate. You can support me and the channel! Read more here: have done videos. toml): DisableChannels (initially -> false) - disables channel restrictions; ControllerLimits (initially -> false) - allows you to install several controllers in the same network. The ME Controller is the core machine required for any Applied Energistics network. 容量 :8,000AE. So putting some thoughts into it will certainly reward more compared to a quick solution. Set the level controller to 1000 torches and point it at an export bus for torches with a crafting. In games like Factorio, getting resources is automated right away. So I've built a rather large network at this point, and I'm not at home so I can't take screenshots, but I'll try to describe. them outside the network. The CPU must contain at least 1 storage component. Large AE2 Network Design Guide - Applied Energistics 2 Tutorial #17 Just get back if/when you have more questions ;)P2P connectors don't transfer power. To summarize what everyone else is saying: if you want a "vanilla" AE2 solution use a quantum bridge otherwise, if you want to extend your System to the. I then use an Ender IO power monitor to turn the reactor on and off. manually mine. If there's "Extra Cells 2" in your pack, the biggest storage cells are 16M (instead of 64k). An ME System is a system in Applied Energistics 2 that uses a ME Controller and a combination of other items found in Applied Energistics 2. The Drawer Controller is a block added by Storage Drawers. The mod allows you to: - Remove channel restrictions; - Connect controllers via cable; - Expand or shrink maximum multiblock size from controllers; - Turn off power usage. Der Mod der das möglich macht, nennt sich applied Energistics 2. Read below for info and updates on the s. Install the highest level of storage upgrade that you can on the drawers, and a void upgrade (which will delete anything going to a drawer that is. More than enough channels. The mod allows you to: Remove channel restrictions; Connect controllers via cable; Expand or shrink maximum multiblock size from controllers. It would be nice to be able to simply configure each item using the ME Interface, so that only a. By AlgorithmX2. シングルプレイ. If you have Immersive Engineering, you can get a mod, called ZettaIndustries, that has ME cables which can span a long way and give you stable connection through unloaded chunks.